Sized for the load. Integrated with the panel.

DG sets, UPS, inverters and servo stabilisers, selected by load profile, integrated with the main electrical panel and commissioned end to end. The backup-power scope is part of the electrical scope, not a separate vendor with separate accountability.

What we install

Four families of backup & conditioned power.

Each technology fits a different load and a different downtime tolerance. A hospital ICU and a residential apartment need different equipment, and we specify them differently.

DG / 01

Diesel generator sets

Sized by sanctioned load and essential / critical load split. Acoustic enclosures (CPCB-compliant), AMF panels for unattended automatic start, day-tank and bulk diesel storage, exhaust routing, cable trench to main panel changeover.

UPS / 02

Uninterrupted power supply (UPS)

Pure-sine-wave UPS, single phase and three phase, online double-conversion. Typical spec: THD < 10 %, PF > 0.9, efficiency at all loads > 0.93, with sealed maintenance-free battery bank and rack. Sized for the actual critical load plus the runtime you need (15, 30 or 60 minutes).

STAB / 03

Servo voltage stabilisers

Atandra KRYKARD, in oil-cooled and air-cooled families, single and three phase. Tight voltage regulation (typically ± 1 %) for voltage-sensitive loads: medical imaging, jewellery showroom lighting, IT racks, sensitive lab equipment, broadcast and precision machining. See the Atandra page.

INV / 04

Inverters & home backup

Sine-wave home and small-commercial inverters for residential bungalows, small clinics, retail outlets. Sized to support essential lighting, fans and small appliances; battery bank dimensioned for the load profile.

How we size

The four questions we ask before we recommend.

Getting the selection right starts with the load, not the catalogue. We work through these four questions on every project before we quote.

Q / 01What's the protected load?
Not the whole building, only the equipment that has to stay on. ICU, MRI, server racks, security panel, emergency lighting. Critical, essential and non-essential separated out, with the arithmetic written down.
Q / 02What's the downtime tolerance?
Seconds (UPS), tens of seconds (UPS + DG with AMF), minutes (DG alone), hours (inverter). The tolerance drives the family choice before kVA.
Q / 03What's the voltage and quality profile?
Wide grid variation in the area? Servo stabiliser upstream. Sensitive electronics? Online UPS, not line-interactive. Long runtimes? Battery bank against DG diesel, whichever is cheaper to run for your real outage pattern.
Q / 04What's the integration?
Upstream isolator and overcurrent protection for the equipment, downstream distribution off the backup bus, AMF or manual changeover panel, and alarm-status visibility. This is what keeps the install working in year five.

Where we've installed backup power.

Standards we work to.

Get sized

Tell us the load you need to protect.

Send the equipment list and we'll size the DG, UPS or stabiliser kVA, propose the family and quote, with the integration into your main panel included.