Legrand SPDs: the small device that often saves the IT installation behind it.

Type 1 · Type 2 · Type 3 · lightning and switching transient protection

T1 · T2 · T3
Coordinated SPD tiers
DIN-rail mount
Inside the DB
Authorised channel
Nagpur warehouse

Surge Protection Devices clamp transient overvoltage (lightning-induced surges that ride the incoming line, or switching transients from large loads elsewhere on the network) before they reach downstream electronics. A few hundred rupees of SPD often saves the entire IT installation, EMS gateway, or instrumentation cabinet behind it.

Legrand SPDs are organised in three coordinated tiers, Type 1 for direct lightning current at the service entrance, Type 2 for the residual surge at the main DB, Type 3 for the point of use at sensitive equipment. Stocked through the authorised channel for residential, commercial and IT installations.

Range

Four SPD positions in a coordinated installation.

SPDs work in a coordinated chain, Type 1 at the service entrance handles the bulk of a lightning surge, Type 2 at the main DB clamps the residual, Type 3 at the equipment cleans up what's left.

T1 / 01

Type 1: service-entrance SPD

For installations with direct lightning-strike exposure, buildings on hilltops, tall structures, installations with external earth-conductor risk. Spark-gap technology to handle the high impulse currents of a direct strike at the service entrance.

PositionService entrance UseDirect strike exposure
T2 / 02

Type 2: main-DB SPD

The everyday SPD, installed at the main distribution board. Metal-oxide-varistor (MOV) technology, sized for the residual surge that passes a Type 1 (or rides the line without one). The default spec for commercial buildings, IT offices, hospitals.

PositionMain DB UseDefault commercial / IT
T3 / 03

Type 3: point-of-use SPD

For the equipment cabinet itself, servers, EMS gateways, medical-imaging electronics, broadcast equipment. Cleans up the small residual that gets through upstream Type 2 protection. Sized for direct connection to the protected device.

PositionAt the equipment UseSensitive electronics
COORD / 04

Coordinated T1+T2: single device

Combined Type 1 + Type 2 SPDs in a single 4-module DIN-rail body, for installations where the service entrance and the main DB are the same enclosure, or where panel-room space is tight.

FormCombined T1+T2 UseSingle-entry installations

Where SPDs matter most.

Surge protection is not optional on installations with significant downstream electronics. A lightning strike anywhere on the grid within several kilometres can induce a surge that rides the incoming line and destroys IT gear, instrumentation, EMS gateways and HVAC controls, all in a single event. The SPD takes the surge first, sacrificially if necessary, and isolates the downstream loads.

Where SPD specification is critical

Compliance

Authorised Stockist · Legrand SPDs · Nagpur

Authorised Stockist for Legrand SPDs in Nagpur, direct sourcing from Legrand India, genuine product, with Type 1, Type 2 and Type 3 devices for the coordinated chain. Project-rate pricing for contractor, IT-facility and industrial volumes.

Specifying SPDs for an IT, industrial or sensitive-load installation?

Tell us the protection chain (Type 1 / Type 2 / Type 3) and the panel positions, and we'll come back with stock, lead time, and project-rate pricing for contractor and facility volumes.