Hager RCCB & RCBO: the device that protects the human, not just the wire.

RCCB · RCBO · 30 / 100 / 300 mA · types AC and A · IS 12640-2 · ready stock in Nagpur

25 – 125 A
Current ratings
2P · 4P
Pole configurations
30 / 100 / 300 mA
Sensitivity tiers

A Residual Current Device watches the difference between current leaving on the phase and current returning on the neutral. When the two don't match (because some current has found a path to earth, possibly through a human) the RCD trips, fast. Hager builds two devices in this family for the Indian installation: the RCCB (Residual Current Circuit Breaker, leakage protection only, paired with an upstream MCB for overload) and the RCBO (RCCB plus MCB in a single module, leakage and overload protection together).

Shreetuvis is an Authorised Channel Partner for the full Hager RCCB and RCBO range in Nagpur, 25 A to 125 A current ratings, 2-pole and 4-pole configurations, sensitivity tiers of 30 mA for personal protection, 100 mA and 300 mA for equipment and earth-leakage protection, in both AC and A types.

Range

Two products, three sensitivity tiers, two leakage types: one matrix.

Specify an RCD by four coordinates: device type (RCCB or RCBO), sensitivity (30 / 100 / 300 mA), leakage type (AC or A), and current rating (25 A through 125 A in 2P or 4P).

DEVICE / 01

RCCB: Residual Current Circuit Breaker

Leakage protection only. The RCCB sits on the incoming side of a DB or a sub-feeder, trips on earth-leakage, and relies on a separate upstream MCB for overload protection. The simpler, less-expensive option when overload is handled elsewhere.

ProtectsEarth leakage only Width2 mod (2P) / 4 mod (4P)
DEVICE / 02

RCBO: Combined RCCB + MCB

Both protections in a single module. The RCBO trips on leakage and overload, the protective device for a single circuit where you want both earth-leakage discrimination and overcurrent protection in one slot.

ProtectsLeakage + overload Width1 – 2 mod typically
SENS / 03

30 mA: personal protection

The sensitivity tier that protects a human in contact with a fault. Mandatory for residential socket circuits, bathroom circuits, kitchen lines, outdoor outlets. The 30 mA RCD trips fast enough to prevent ventricular fibrillation on a brief shock event.

UsePersonal protection WhereSockets · wet areas
SENS / 04

100 mA & 300 mA: equipment protection

Higher sensitivity tiers for equipment-level protection, selective with downstream 30 mA RCDs (the downstream device trips first, isolating the faulty circuit; the upstream survives, keeping unaffected loads running). Used at sub-main and main RCDs in larger installations.

UseSelectivity · equipment WhereSub-mains · incomers
TYPE / 05

Type AC: standard sinusoidal leakage

The default. Type AC RCDs detect pure sinusoidal AC leakage current, the form of leakage from conventional motors, lighting, heating, sockets feeding plain AC loads. The right choice for most residential and commercial circuits.

DetectsSinusoidal AC leakage UseDefault for most loads
TYPE / 06

Type A: for pulsating DC leakage

Loads with switched-mode power supplies (IT racks, LED drivers, EV chargers, washing machines, induction cooktops) can leak pulsating DC current that a Type AC device misses. Type A detects both AC and pulsating-DC leakage. The current default for any installation with modern electronics.

DetectsAC + pulsating DC UseIT · EV · LED · electronics

RCCB or RCBO: which one belongs in your installation?

The choice is mostly a question of DB layout. If the DB main is an MCB or MCCB and each circuit has its own dedicated MCB, then a single RCCB on the incoming gives all downstream circuits leakage protection, cheaper, simpler, fewer modules. The cost: when a single circuit leaks, the whole DB trips.

If the brief is circuit-level discrimination (the kitchen tripping shouldn't take down the bedroom lights) then each circuit gets its own RCBO (RCCB + MCB in one module). More modules, more cost; but a leakage event on one circuit isolates only that circuit. The right choice for hospital landing distributions, IT facility critical loads, premium residential.

Type AC or Type A: a clear rule

If the load is a pure AC load (incandescent lighting, conventional motors, plain socket loads) Type AC is fine. If the load is anything with electronics, LED drivers, IT racks, EV chargers, modern washing machines, induction equipment, anything with a switched-mode supply, the leakage signature can include a pulsating-DC component that a Type AC device cannot detect reliably. Specify Type A for any modern installation where you don't know the full load profile or where the building will house electronics.

Sensitivity selection

Compliance and certification

Where Hager RCDs go in

Authorised Channel Partner · Hager RCCB & RCBO · Nagpur

Authorised Channel Partner for Hager RCCBs and RCBOs, direct sourcing from Hager India, genuine product, project-rate pricing for contractor and builder volumes, and the full sensitivity / pole / type matrix carried at our Nagpur warehouse. The Hager catalogue's selection tables and discrimination charts are available through the authorised channel, see hager.co.in/downloads. When the choice between Type AC and Type A, or between RCCB and RCBO, depends on a specific load profile, we make the call to Hager India's tech team.

Specifying an RCCB scheme, or quoting an RCBO ladder?

Send the load schedule or DB single-line. We'll come back with the matched RCD specification (sensitivity tier, type, pole configuration, current rating) and project-rate pricing for contractor and builder volumes.