Shreetuvis Technologies Private Limited Get a quote
Authorised Stockist · DPX³ MCCBs · DMX³ ACBs · Nagpur

Legrand DPX³ & DMX³: main-panel heavy protection.

DPX³ MCCBs up to 1600 A · DMX³ ACBs in three frame sizes · LV main and feeder switchgear

up to 1600 A
DPX³ MCCB range
3 frame sizes
DMX³ ACB range
Authorised channel
Nagpur warehouse

DPX³ and DMX³ are Legrand's heavy-protection families: the MCCBs and Air Circuit Breakers that sit at the LV-panel main and on the heavy outgoing feeders. Above DX³ on the panel hierarchy, coordinated through Legrand's published selectivity tables so an upstream DPX³ trip clears the fault before the downstream DX³ MCB sees it.

Specified on industrial mains, commercial-building incomers, hospital landing distributions, township DBs and panel-builder switchgear. Stocked through the authorised channel for panel-builder, contractor and industrial facility volumes.

Range

Four heavy-protection sub-ranges. The main side of an LV panel.

DPX³ covers the MCCB tier: moulded-case breakers in three frame sizes through 1600 A. DMX³ covers the ACB tier: air circuit breakers for industrial mains.

DPX³ / 01

DPX³ MCCBs: up to 1600 A

Moulded-case circuit breakers in 160 A, 250 A, 630 A and 1600 A frame sizes. Thermal-magnetic and electronic trip-unit variants: LSI / LSIG / electronic with current and earth-fault settings. For the main incoming and outgoing of LV panels.

Frames160 · 250 · 630 · 1600 A TripThermal · electronic LSIG
DMX³ / 02

DMX³ ACBs: air circuit breakers

Air circuit breakers in three frame sizes, fixed and draw-out variants. For the main incoming of large industrial panels, township main DBs, hospital substation outgoings. Microprocessor trip units with full LSIG protection and communication options.

FormsFixed · draw-out TripMicroprocessor LSIG
ACC / 03

Accessories and trip units

Auxiliary contacts, shunt trips, undervoltage releases, motor-operating mechanisms, rotary handles, key locks, padlock interlocks, the supporting hardware that turns a bare DPX³ or DMX³ into a working main breaker.

ItemsAux · UVR · motor · locks UsePanel-build hardware
MOTOR / 04

Motor protection: DPX³ variants

DPX³ MCCB variants with motor-protection trip curves, designed for the inrush current of large industrial motors. For pump-house panels, compressor mains, lift-shaft incomers.

UseMotor-start loads TripMotor-protection curve

Where DPX³ and DMX³ fit in the panel hierarchy.

DPX³ MCCBs sit at the LV-panel main and on the heavy outgoing feeders, typically 160 A or 250 A on a commercial building main, 630 A or 1600 A on an industrial main. DMX³ ACBs sit one tier higher, on industrial mains where the breaking capacity, draw-out maintainability, and microprocessor trip-unit features matter. Below both sit DX³ MCBs on the modular outgoings, coordinated through Legrand's published selectivity tables.

How a DPX³ / DMX³ panel typically goes together

Compliance

Authorised Stockist · Legrand DPX³ & DMX³ · Nagpur

Authorised Stockist for Legrand DPX³ and DMX³ in Nagpur, direct sourcing from Legrand India, genuine product, with the frame sizes panel builders specify on real switchgear orders. Project-rate pricing for panel-builder and contractor volumes. Trip-unit configuration, selectivity-table references and OEM tech access available through the authorised channel.

Specifying DPX³ or DMX³ for a panel build?

Send the SLD or the main-panel BoM, and we'll come back with the DPX³ / DMX³ BoM, frame sizes, trip-unit configuration, accessories. Project-rate pricing for panel-builder and industrial volumes.