Hager h3+: the current-generation MCCB for serious main switchgear.

P160 · P250 · P400 frames · TM and LSI / LSIG trip · up to 110 kA · IS 13947-2

P160 · P250 · P400
Frame sizes
25 – 630 A
Current rating range
25 → 110 kA
Breaking capacity tiers

h3+ is Hager's current-generation MCCB platform, designed around a smaller frame footprint than the previous-generation MCCBs at equivalent ratings, with both traditional thermal-magnetic and electronic trip technologies available across the frame ladder. The compact footprint matters at the panel-design stage: an h3+ saves panel real estate that a building-services consultant can spend on cable terminations or sub-section spacing.

Three frames cover most of the Indian LV-panel installed base (P160 for 25 A to 160 A, P250 for 100 A to 250 A, P400 for 250 A to 400 A) with higher frames extending to 630 A and beyond. Pole configurations are 3-pole and 4-pole; breaking capacity comes in five tiers from 25 kA up to 110 kA, picked against the available fault current at the device's installed position.

Selection coordinates

Six things to decide before specifying an h3+ MCCB.

The h3+ family is selected on six coordinates: frame size, current rating within the frame, breaking-capacity tier, trip technology, pole configuration, and any optional accessories (shunt trip, undervoltage release, energy measurement). The tiles below walk through each.

FRAME / 01

P160: small frame, 25 to 160 A

The compact frame. Footprint optimised for tight-cabin installations and the MCCB-Enclosure variants of Novello+ DBs. Residential-township DB-room mains, small commercial fit-out incoming, retail-outlet main.

Ratings25 · 40 · 63 · 80 · 100 · 125 · 160 A Poles3P / 4P
FRAME / 02

P250: mid frame, 100 to 250 A

Mid-frame MCCB for substantial commercial mains. Hospital main panel, hotel-floor main, mid-size factory sub-main, retail-mall feeder. Overlaps with P160 in the 100 – 160 A range when higher breaking capacity is required.

Ratings100 · 125 · 160 · 200 · 250 A Poles3P / 4P
FRAME / 03

P400: large frame, 250 to 400 A (to 630 A)

Large-frame MCCB for plant-level mains and main switchboards. 33/11 kV substation LT-side outgoing, industrial main panel incoming, large-mall HVAC sub-main. Higher frames within the family extend to 500 A and 630 A.

Ratings250 · 320 · 400 · 500 · 630 A Poles3P / 4P
TRIP / 04

Thermal-Magnetic (TM) trip

Fixed-setting magnetic and thermal release. The traditional MCCB technology, robust, well-understood, no auxiliary power required. Specify TM when the panel's protection settings are known at design stage and don't need to adjust over the building's life.

TechThermal-magnetic AdjustFixed by rating
TRIP / 05

Electronic LSI / LSIG trip

Microprocessor-based trip. Long-time (overload), Short-time (delayed short-circuit), Instantaneous, and optionally Ground-fault, all with adjustable settings on the unit. Choose when selectivity must be tunable, future-load headroom must be reserved, or earth-fault discrimination is critical.

TechMicroprocessor (LSI / LSIG) AdjustOn-unit settings
BREAKING / 06

Breaking capacity: 25 to 110 kA

Five tiers across the h3+ family. 25 kA for far-from-source positions, 36 / 50 kA for typical commercial mains, 70 / 110 kA close to the transformer LT side or where calculated fault currents are high. Always specify against the available fault current, not against a "safer is bigger" intuition.

Tiers25 · 36 · 50 · 70 · 110 kA Specify byAvailable fault current

The decision rule for specifying an h3+.

An h3+ MCCB is specified in four sequential decisions. One: pick the frame size against the maximum continuous current, the highest rating you ever expect the device to carry plus a small headroom for future growth. Two: pick the trip technology, thermal-magnetic if the panel's protection settings are fixed by design, electronic LSI / LSIG if the settings will move or if earth-fault selectivity matters. Three: pick the breaking capacity tier against the calculated available fault current at the installed position, a calculated number, not a guessed one. Four: pick the pole configuration, 3P for 3-phase loads with neutral-earthed system, 4P where the neutral must switch with the phases (typical for DG-changeover-fed circuits).

The accessories (shunt trip coil, undervoltage release, auxiliary contacts, motorised mechanism, communication module) are decided last, against the panel-control philosophy. Most general MCCB specifications don't need them; safety-critical and automation-integrated panels often do.

Selectivity with downstream devices

The point of fitting an MCCB at the main is to keep the building running when a single downstream circuit faults. Selectivity is the property that the downstream MCB trips before the upstream h3+, clearing the fault while the rest of the building stays live. Hager publishes detailed selectivity tables for h3+ against the company's MCB families: the curves and the I²t energy let-through values. These references are available through the authorised channel: any panel design where selectivity actually matters should be coordinated against the published tables before the order is placed.

Electronic trip: energy measurement and communication

Some electronic-trip h3+ variants include an integrated energy-measurement module (voltage, current, power, energy consumption, harmonic profile) and a communication interface (Modbus or similar) for facility-management integration. For an IT facility, a hospital, or a large commercial building where energy data feeds the BMS, the electronic h3+ replaces a separate MCCB plus power-meter combination.

Compliance and certification

Where Hager h3+ MCCBs go in

Authorised Channel Partner · Hager h3+ MCCB · Nagpur

Authorised Channel Partner for Hager h3+, direct sourcing from Hager India, genuine product, with the P160 / P250 / P400 frame ladder stocked at our Nagpur warehouse across the standard breaking-capacity tiers. Project-rate pricing for contractor and builder volumes. The full h3+ selection tables, time-current curves, let-through I²t energy curves and selectivity tables are available through the authorised channel, see the h3+ catalogue page at hager.co.in.

Specifying an h3+ MCCB, or quoting a panel main?

Send the panel single-line, the expected continuous current, and the available fault current at the device position, or just the BoQ line items. We'll come back with the matched h3+ specification, lead time, and project-rate pricing for contractor and builder volumes.